Show simple item record

dc.contributor.authorMushtaq, Faizah
dc.contributor.authorSoulby, Andrew
dc.contributor.authorBoyle, Patrick
dc.contributor.authorPapoutselou, Efstratia
dc.contributor.authorNunn, Terry
dc.contributor.authorHartley, Douglas
dc.date.accessioned2024-04-19T09:30:38Z
dc.date.available2024-04-19T09:30:38Z
dc.date.issued2024-04-19
dc.identifier.urihttps://rdmc.nottingham.ac.uk/handle/internal/11403
dc.description.abstractA recent study from our research group showed that experienced cochlear implant (CI) users can independently perform their own cochlear health (CH) recordings at home, thanks to advances in CI telemetry. This allows measurements to be taken at regular intervals and over long periods of time. Whilst this is not yet currently available in routine clinical practice, the wealth of data that can be generated in this way has numerous potential applications, including helping to maximise the benefit patients receive from CIs by allowing clinicians to tailor CI programming strategies based on each individual’s own responses, explaining some of the variation in CI outcomes and creating tools to evaluate the safety and efficacy of novel adjunctive treatments for hearing loss. In this project, we assessed the stability of early post-implantation electrode impedances, electrically-evoked compound action potentials (eCAPs) and electrocochleography (ECochGs) in a group of newly implanted CI recipients. Specifically, eight subjects used the Active Insertion Monitoring system by Advanced Bionics to take the three recordings on a daily basis at home for three months, starting from the first day after CI surgery. Group level measurement validity was 93.7% for impedances, 93.1% for eCAPs and 83.7% for ECochGs. Impedances gradually increased over the first ten days and likely associated with the initial intracochlear inflammatory response to the electrode array, before decreasing and immediately after CI switch-on and, subsequently stabilizing thereafter. eCAP thresholds also showed good long-term stability over time and some subjects consistently displayed absent thresholds at one or more electrodes, potentially indicating regions of poor neural health. Since subjects were expected to have very little residual hearing, having met UK NICE guidelines for cochlear implantation, it was unsurprising that most ECochG thresholds did not reach the signal-to-noise criterion of 2:1 adopted by the AIM system. For the very small number of subjects that did show a considerable proportion of valid thresholds, these were relatively stable. We conclude that eCAPs and electrode impedances are promising objective measurements for evaluating CH in newly implanted CI recipients.en_UK
dc.language.isoenen_UK
dc.publisherThe University of Nottinghamen_UK
dc.rightsCC-BY*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subject.lcshCochlear implantsen_UK
dc.subject.lcshElectrocochleographyen_UK
dc.subject.meshCochlear Implantsen_UK
dc.subject.meshAudiometry, Evoked Responseen_UK
dc.titleSelf-assessment of cochlear health by new cochlear implant recipients: daily impedance, electrically-evoked compound action potential and electrocochleography measurements over the first three postoperative monthsen_UK
dc.typeDataset
dc.identifier.doihttp://doi.org/10.17639/nott.7405
dc.subject.freeCochlear implant, hearing loss, electrode impedance, electrocochleography, electrically-evoked compound action potential, neural response telemetryen_UK
dc.subject.jacsSubjects Allied to Medicine::Medical technologyen_UK
dc.subject.jacsSubjects Allied to Medicine::Aural & oral sciences::Audiologyen_UK
dc.subject.lcW Medicine and related subjects (NLM Classification)::WV Otolaryngologyen_UK
uon.divisionUniversity of Nottingham, UK Campus::Faculty of Medicine and Health Sciences::School of Medicineen_UK
uon.funder.controlledOtheren_UK
uon.datatypeObjective measures of cochlear healthen_UK
uon.funder.freeRinri Therapeutics and a UKRI Innovation Scholars secondmenten_UK
uon.collectionmethodSelf recorded using an electronic tableten_UK
uon.institutes-centresUniversity of Nottingham, UK Campus::NIHR Nottingham Hearing Biomedical Research Uniten_UK


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • Public Research Data
    A collection of research data, held in this repository, that is publicly available, except where individual embargoes apply

Show simple item record

CC-BY
Except where otherwise noted, this item's license is described as Creative Commons by Attribution