File description: slab_mesh_data.zip: Archive containing the reconstruction files used in the section of the article that study the reconstruction on a slab model (section 4.1) It contains eight folders with simulation results in different conditions. - "20170518_060527_VarSpacing_ReconWhole_slabHD_muscleSpec_40_40_20fmodelData_r1p5_2sources_z14": Reconstructions of two simulated sources separated by 4, 6 or 8 mm using the whole mesh. - "20170616_201832_VarSpacing_reconSliceVert_slabHD_muscleSpec_40_40_20fmodelData_r1p5_2sources_z14": Reconstructions of two simulated sources separated by 4, 6 or 8 mm using a permissible region without depth information (vertical slice). - "20170714_145637_VarSliceVert_slabHD_muscleSpec_40_40_20fmodelData_r1p5_z5": Reconstructions of one simulated source using a permissible region without depth information (vertical slice) - "20170714_150043_reconVarDynamicVOI_slabHD_muscleSpec_40_40_20fmodelData_r1p5_z5": Reconstructions of one simulated source using a permissible region tuned with depth information (from ultrasound) and dynamic of the jacobian matrix. - "20170720_113843_reconWhole_slabHD_muscleSpec_40_40_20fmodelData_r1p5_z5": Reconstruction of one simulated source using the whole mesh. - "20170726_175437_reconVarDynamic_slabHD_muscleSpec_40_40_20fmodelData_r1p5_2sources_z14_d6": Reconstruction of two simulated sources separated by 6 mm using a permissible region tuned with depth information (from ultrasound) and dynamic of the jacobian matrix. - "20170726_175438_reconVarDynamic_slabHD_muscleSpec_40_40_20fmodelData_r1p5_2sources_z14_d4": Reconstruction of two simulated sources separated by 4 mm using a permissible region tuned with depth information (from ultrasound) and dynamic of the jacobian matrix. - "20170726_175558_reconVarDynamic_slabHD_muscleSpec_40_40_20fmodelData_r1p5_2sources_z14_d8": Reconstruction of two simulated sources separated by 8 mm using a permissible region tuned with depth information (from ultrasound) and dynamic of the jacobian matrix. -- digimouse_data.zip: Archive containing the reconstruction files used in the section of the article that study the reconstruction on the digimouse numerical model (section 4.2) It contains six folders with simulation results in different conditions. - "20170714_163733_reconSliceVert_digimouse_spec_5_blt_21_68_9p2_1p5_fModelData": Reconstruction of one simulated source 9 mm deep inside the animal using a permissible region that do not include depth information (Vertical slice). - "20170714_164739_reconSliceVert_digimouse_spec_5_blt_22p3_68_10p4_1p5_fModelData": Reconstruction of one simulated source 7.2 mm deep inside the animal using a permissible region that do not include depth information (Vertical slice). - "20170715_053753_reconWhole_digimouse_spec_5_blt_22p3_68_10p4_1p5_fModelData": Reconstruction of one simulated source 7.2 mm deep inside the animal using the whole mesh. - "20170715_055739_reconWhole_digimouse_spec_5_blt_21_68_9p2_1p5_fModelData": Reconstruction of one simulated source 9 mm deep inside the animal using the whole mesh. - "20170718_155154_reconVarDynamicVOI_digimouse_spec_5_blt_22p3_68_10p4_1p5_fModelData": Reconstruction of one simulated source 7.2 mm deep inside the animal using a permissible region tuned with depth information (from ultrasound) and dynamic of the jacobian matrix. - "20170718_155201_reconVarDynamicVOI_digimouse_spec_5_blt_21_68_9p2_1p5_fModelData": Reconstruction of one simulated source 9 mm deep inside the animal using a permissible region tuned with depth information (from ultrasound) and dynamic of the jacobian matrix. -- gel_data.zip: Archive containing the files used in the last part of the study of the article (Section 4.3). It contains three folders names "IVIS Data", "reconstruction" and "Ultrasound". "IVIS Data": Images taken by the IVIS system of a scattering agar gel with a chemiluminescent light source embedded inside the gel. "reconstruction": Tomographic reconstruction in NIRFAST in different conditions - "20170622_150845_reconWhole_slab_specMuscle_0p70_70_40_20_CSU20161118141404": Reconstruction of the shallow CL source using the whole mesh - "20170623_151041_reconWhole_slab_specMuscle_0p70_70_40_20_CSU20161118141751": Reconstruction of the deep CL source using the whole mesh - "20170724_184216_reconVarDynamic_slab_specMuscle_0p70_70_40_20_CSU20161118141404": Reconstruction of the shallow CL source using prior knowledge on source position and limiting the dynamic - "20170724_142507_reconVarDynamic_slab_specMuscle_0p70_70_40_20_CSU20161118141751": Reconstruction of the deep CL source using prior knowledge on source position and limiting the dynamic "ultrasound": Ultrasound image of the gel to identify the depth of the source. --